Bugfix: ac-adapter is sometimes called ADP1 in sysfs instead of AC
[monky] / src / linux.c
index a41220e..3185217 100644 (file)
@@ -1336,6 +1336,8 @@ void get_acpi_fan(char *p_client_buffer, size_t client_buffer_size)
 
    Update: it seems the folder name is hardware-dependent. We add an aditional adapter
    argument, specifying the folder name.
+
+   Update: on some systems it's /sys/class/power_supply/ADP1 instead of /sys/class/power_supply/AC
 */
 
 void get_acpi_ac_adapter(char *p_client_buffer, size_t client_buffer_size, const char *adapter)
@@ -1344,14 +1346,20 @@ void get_acpi_ac_adapter(char *p_client_buffer, size_t client_buffer_size, const
 
        char buf[256];
        char buf2[256];
+       struct stat sb;
        FILE *fp;
 
        if (!p_client_buffer || client_buffer_size <= 0) {
                return;
        }
 
-       snprintf(buf2, sizeof(buf2), "%s/%s/uevent", SYSFS_AC_ADAPTER_DIR, adapter);
-       fp = open_file(buf2, &rep);
+       if(adapter)
+               snprintf(buf2, sizeof(buf2), "%s/%s/uevent", SYSFS_AC_ADAPTER_DIR, adapter);
+       else{
+               snprintf(buf2, sizeof(buf2), "%s/AC/uevent", SYSFS_AC_ADAPTER_DIR);
+               if(stat(buf2, &sb) == -1) snprintf(buf2, sizeof(buf2), "%s/ADP1/uevent", SYSFS_AC_ADAPTER_DIR);
+       }
+       if(stat(buf2, &sb) == 0) fp = open_file(buf2, &rep); else fp = 0;
        if (fp) {
                /* sysfs processing */
                while (!feof(fp)) {